冷却
上級

Iceotope KU:L (Precision Immersion 1U Server・2024年)(アイスオトープクール)

2024年Iceotope (英Sheffield・2005年Peter Hopton創業・19年継続 Precision Immersion Cooling specialty brand・累計funding $30M+/Series B・HPE + Schneider Electric partnerships) 発表KU:L Precision Immersion・Server-level Precision Immersion Cooling (1U Server chassis内Dielectric fluid sealed + Server full immersion within chassis・Tank-style全体immersion vs Server-level precision immersion differentiated approach) + Submer SmartCoolant similar mineral oil-based dielectric fluid + Per-Server-level cooling Industry-leading precision・Edge Datacenter + Hospital Datacenter + Telecom Edge use cases。

0 回閲覧
0 いいね
2026/5/20 更新
関連タグ
iceotope
kul-precision-immersion
1u-server-immersion
edge-datacenter
hpe-partnership
precision-cooling

概要

Iceotope KU:L は、2024年Iceotope (英Sheffield本社・2005年Peter Hopton創業・19年継続 Precision Immersion Cooling specialty brand・累計funding $30M+/Series B・HPE Hewlett Packard Enterprise partnership 2021年-継続 + Schneider Electric partnership 2022年-継続・Iceotope KU:L technology HPE + Schneider Electric channel distribution + Mainstream datacenter market access) が発表したKU:L Precision Immersion・Server-level Precision Immersion Cooling・Iceotope 19年Precision Immersion specialty brand heritage継承 + 2005年初期Precision Immersion concept独自開発 + 業界Pioneer position確立。Precision Immersion Cooling architecture = 1U Server chassis内Dielectric fluid sealed (Standard 1U server form factor内 Dielectric fluid sealed + Server component fluid内immersion・Industry-standard 1U rack-mountable form factor compatibility) + Server full immersion within chassis (1U chassis enclosed environment・Tank-style全体immersion vs Server-level precision immersion differentiated approach・Submer SmartPodX Pod-style + GRC OptiCool Tank-style vs Iceotope KU:L 1U Server-level)・Submer SmartCoolant similar mineral oil-based dielectric fluid (Industry-standard mineral oil-based Single-Phase Immersion fluid・Iceotope proprietary fluid formulation類似) + Per-Server-level cooling Industry-leading precision (Per-Server fluid management + Individual server replacement-able + Standard rack-mountable maintenance workflow compatibility) ・PUE 1.05-1.08 (Submer Pod-style 1.03-1.05 vs Iceotope Server-level 1.05-1.08・若干Higher PUE due to Per-Server scale + Submer Larger pod scale efficiency advantage・但しIceotope Per-Server maintenance flexibility advantage)・Edge Datacenter + Hospital Datacenter + Telecom Edge use cases (Edge computing deployment locations + Mainstream datacenter integration・Tank-style immersion deployment vs Standard rack-mountable 1U Server compatibility・Edge Datacenter + Hospital環境 sensitive deployments + Telecom Edge compute locations)・HPE + Schneider Electric partnerships で Industry-wide reach・HPE Iceotope KU:L sub-branding HPE customer base access + Schneider Electric Datacenter infrastructure integration + Mainstream datacenter market penetration acceleration。

主な特徴・仕組み

  • Cooling Type: Server-level Precision Immersion (1U Server chassis内sealed・Per-Server precision)
  • Form Factor: 1U Server chassis (Industry-standard rack-mountable form factor compatibility)
  • Dielectric Fluid: Iceotope proprietary mineral oil-based dielectric fluid (Single-Phase)
  • PUE: 1.05-1.08 (Submer Pod-style 1.03-1.05 vs slightly higher due to Per-Server scale)
  • Per-Server Maintenance: Individual server replacement-able + Standard rack-mountable workflow
  • Partnerships: HPE (Hewlett Packard Enterprise・2021年-) + Schneider Electric (2022年-)
  • Vendor: Iceotope (2005年設立・Sheffield UK・19年Industry pioneer position)
  • Use Cases: Edge Datacenter + Hospital Datacenter + Telecom Edge + Mainstream rack-mountable integration
  • Differentiation: Tank-style全体immersion vs Server-level precision immersion approach
  • Industry Position: Precision Immersion Cooling specialty brand + Pioneer 19年heritage

スペック比較表

Immersion Cooling Approach (2024)Form FactorPer-Server MaintenancePUEIndustry Position
Iceotope KU:L1U Server chassis◎ Individual replace1.05-1.08Pioneer + HPE partnership
Submer SmartPodXPod-style (4U-8U)△ Pod-level1.03-1.05Industry-leading PUE
GRC OptiCool 2-PhaseTank-style全体△ Tank-level1.02-1.042-Phase specialty
CoolIT D2C CDUCold plate Server-mount◎ Standard maintenance1.10-1.15Direct-to-Chip dominant
Conventional Air CooledStandard rack-mountable◎ Standard1.4-1.6Industry-standard

具体例・対応製品

  • Iceotope KU:L 1U Server: $20K-$40K per 1U Server cooling cost incremental
  • HPE x Iceotope KU:L (HPE sub-brand): HPE channel distribution + HPE customer access
  • Iceotope KU:L Edge variant: Smaller form factor for Edge AI deployment
  • Schneider Electric integration: Datacenter infrastructure integrated solution
  • 競合 Submer SmartPodX: Pod-style 4U-8U + 240kW capacity + Higher PUE efficiency
  • 競合 CoolIT D2C CDU: Direct-to-Chip Liquid + Server-mount cold plate + Higher PUE

自作PCでの選び方・注意点

Iceotope KU:L は「Mainstream rack-mountable 1U Server form factor compatibility (Standard rack-mountable 1U Server chassis Industry-standard form factor compatibility・Per-Server cooling individual maintenance flexibility + Standard datacenter maintenance workflow continuity・Tank-style immersion deployment learning curve avoidance)」「HPE + Schneider Electric partnerships (HPE sub-branding + HPE customer base channel access + Schneider Electric Datacenter infrastructure integration + Mainstream datacenter market penetration access)」「Edge Datacenter + Hospital + Telecom Edge use cases (Edge computing deployment locations sensitive environments + Mainstream datacenter integration vs Tank-style immersion deployment limitations)」用途のServer-level Precision Immersion Cooling specialty brand。1U Server chassis form factor (Industry-standard rack-mountable form factor compatibility) で Mainstream datacenter integration friendly + Per-Server replacement-able maintenance flexibility + Standard datacenter workflow continuity + Iceotope unique differentiated positioning vs Tank-style全体immersion competitors (Submer SmartPodX + GRC OptiCool)・Tank-style approach (Server entire batch immersion + Pod / Tank entire unit maintenance) vs Iceotope Per-Server approach (Individual server replacement + Standard rack-mountable maintenance) で Datacenter operator preference + Maintenance workflow compatibility分岐。HPE + Schneider Electric partnerships (HPE Hewlett Packard Enterprise partnership 2021年-継続・HPE channel distribution + HPE customer base access + HPE x Iceotope KU:L sub-branding・Schneider Electric partnership 2022年-継続・Datacenter infrastructure integrated solution + Mainstream datacenter market penetration access) で Industry-wide reach acceleration + Smaller specialty brand Iceotope vs Larger HPE + Schneider Electric channels combined market access. Edge Datacenter + Hospital Datacenter + Telecom Edge use cases (Edge computing deployment locations + Hospital環境 noise-sensitive + Mission-critical reliability + Telecom Edge compute locations) で Mainstream datacenter integration impossible Tank-style immersion vs Iceotope 1U Server form factor compatibility differentiated value。但しPUE 1.05-1.08 vs Submer 1.03-1.05 (若干higher PUE due to Per-Server scale efficiency disadvantage) + Submer Pod-style 240kW per pod high capacity vs Iceotope Per-Server scale lower capacity (Large-scale AI Datacenter deployment Submer Pod-style preference・Edge + Mainstream rack-mountable Iceotope Per-Server preference) のScale + Use case alignment判断必要。

関連用語との違い

  • vs Submer SmartPodX: Iceotope 1U Server per-server precision + HPE partnership・Submer Pod-style 4U-8U + 240kW high capacity + Lower PUE
  • vs GRC OptiCool 2-Phase: Iceotope Single-Phase + 1U Server form factor・GRC 2-Phase Tank-style + Novec specialty fluid
  • vs CoolIT D2C CDU: Iceotope Full Immersion 1U chassis・CoolIT Direct-to-Chip + Cold plate Server-mount + Different cooling architecture

よくある質問(FAQ)

Q1: Per-Server precision vs Pod/Tank-style 違いは? A: Per-Server precision (Iceotope KU:L 1U Server chassis individual・Individual server replacement-able + Standard rack-mountable maintenance workflow continuity + Mainstream datacenter integration friendly) vs Pod/Tank-style (Submer SmartPodX Pod + GRC OptiCool Tank・Higher per-unit capacity + Lower PUE + Tank-level maintenance + New maintenance workflow learning curve)・Use case + Maintenance workflow preference依存分岐。

Q2: HPE + Schneider Electric partnership 影響は? A: HPE (Hewlett Packard Enterprise・Industry-leading Datacenter server manufacturer + Industry-wide customer base) + Schneider Electric (Datacenter infrastructure dominant brand + Industry-leading PDU + UPS + Datacenter infrastructure portfolio) partnerships で Iceotope specialty brand mainstream market access acceleration + HPE Servers + Iceotope KU:L cooling integrated solution + Schneider Electric Datacenter infrastructure integration + Mainstream datacenter customer deployment friendly。

Q3: 19年Precision Immersion specialty brand heritage 価値は? A: Iceotope (2005年設立・Sheffield UK・19年継続 Precision Immersion Cooling specialty brand・累計funding $30M+/Series B・Pioneer position確立) で Industry-leading Precision Immersion expertise + 19年technology evolution + 累計deployment experience + HPE + Schneider Electric partnerships credibility + Long-term Industry-leading position + Datacenter operator critical reliability requirement alignment。

まとめ

Iceotope KU:L = 2024年Iceotope発表のServer-level Precision Immersion Cooling 1U Server chassis。Industry-standard rack-mountable form factor compatibility + Per-Server precision immersion + Mineral oil-based dielectric fluid + PUE 1.05-1.08 + HPE + Schneider Electric partnerships + Edge Datacenter + Hospital + Telecom Edge use cases + Iceotope 19年Precision Immersion specialty brand Pioneer position。

この記事について
カテゴリー冷却
難易度上級
作成日2026/5/20